Acute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load

dc.creatorMarcel Bahia Lanza
dc.creatorAntônio Eustáquio de Melo Pertence
dc.creatorAndré G. P. Andrade
dc.creatorGustavo H. Peixoto
dc.creatorLeonardo Bonato Felix
dc.creatorMauro Heleno Chagas
dc.date.accessioned2023-07-19T19:15:05Z
dc.date.accessioned2025-09-09T00:51:25Z
dc.date.available2023-07-19T19:15:05Z
dc.date.issued2017-11-07
dc.description.abstractO objetivo deste estudo foi propor um dispositivo mecânico que acoplado a uma cadeira flexora aumente a carga mecânica durante toda a ação excêntrica (ECC) e comparar a atividade muscular durante a utilização do dispositivo proposto. Quinze mulheres fisicamente ativas foram recrutadas e realizaram dois diferentes protocolos (controle e sobrecarga ECC). O protocolo controle foi realizado com ações concêntricas (CON) e ECC com carga iguais (60% de uma repetição máxima), enquanto o protocolo de sobrecarga ECC consistiu em ações ECC com 40% mais de carga do que as ações CON. A ativação muscular dos músculos biceps femoris (BF) e gastrocnemius medialis (GM) foi medida por meio de eletromiografia de superfície. Durante as ações ECC foi observada uma maior ativação do BF durante o protocolo de sobrecarga quando comparado ao protocolo controle (p = 0,032). No entanto, GM não apresentou diferenças na ativação entre os protocolos (p = 0,439). O dispositivo mecânico proposto foi capaz de aumentar a carga durante a ação ECC e, consequentemente, a atividade muscular do BF.
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
dc.format.mimetypepdf
dc.identifier.doihttps://doi.org/10.1590/1980-0037.2017v19n4p375
dc.identifier.issn1980-0037
dc.identifier.urihttps://hdl.handle.net/1843/56752
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofRevista Brasileira Cineantropom Humano
dc.rightsAcesso Aberto
dc.subjectContração Muscular
dc.subjectEletromiografia
dc.subjectTreinamento de resistência
dc.subject.otherContração muscular
dc.subject.otherEletromiografia
dc.subject.otherTreinamento de resistência
dc.titleAcute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load
dc.title.alternativeResposta neuromuscular aguda durante um protocolo de sobrecarga excêntrica usando um dispositivo mecânico para aumentar a carga
dc.typeArtigo de periódico
local.citation.epage384
local.citation.issue4
local.citation.spage375
local.citation.volume19
local.description.resumoThe aim of this study was to propose a mechanical device that could increase the mechanical load during the entire eccentric (ECC) action on a knee flexor machine and to compare the muscular activity when the device was used during a testing proto col. Fifteen physically active women were recruited, and they performed two protocols: control and eccentric overload. Control protocol was performed with concentric (CON) and ECC actions with similar load (60% of one repetition maximum) whilst eccentric overload protocol consisted of ECC actions with 40% more load than CON actions. Muscular activation was measured using surface electromyography of the biceps femoris (BF) and the gastrocnemius medialis (GM) muscles. ECC actions presented a higher muscular activation during eccentric overload protocol than control protocol for BF (p = 0.032), but not for the GM (p = 0.439). The mechanical device increased the mechanical load during the ECC muscle action and consequently increased the amplitude of the neural drive to the BF muscle; however, it did not increase the amplitude of the neural drive to the GM muscle.
local.identifier.orcidhttps://orcid.org/0000-0002-1955-8990
local.publisher.countryBrasil
local.publisher.departmentEEF - DEPARTAMENTO DE ESPORTES
local.publisher.departmentEEFFTO - ESCOLA DE EDUCAÇÃO FISICA, FISIOTERAPIA E TERAPIA OCUPACIONAL
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICA
local.publisher.initialsUFMG
local.url.externahttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2017v19n4p375

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Acute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load.pdf
Tamanho:
270.9 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: