Study on the maximum pressures of a solar-assisted R744 direct expansion heat pump for water heating

dc.creatorJéssica Cristina Campos Miranda Silva
dc.creatorLuiz Machado
dc.creatorWillian Moreira Duarte
dc.date.accessioned2023-09-06T23:57:05Z
dc.date.accessioned2025-09-09T00:04:20Z
dc.date.available2023-09-06T23:57:05Z
dc.date.issued2022
dc.format.mimetypepdf
dc.identifier.urihttps://hdl.handle.net/1843/58539
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.rightsAcesso Aberto
dc.rightsAtribuição 3.0 Portugal
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pt/
dc.subjectEvaporadores
dc.subject.otherNumeric model
dc.subject.otherDX-SAHP
dc.subject.otherPressure in the evaporator
dc.subject.otherSolar Assisted Heat Pump
dc.subject.otherR744 (CO2)
dc.titleStudy on the maximum pressures of a solar-assisted R744 direct expansion heat pump for water heating
dc.typeArtigo de evento
local.citation.epage10
local.citation.issue19
local.citation.spage1
local.description.resumoThe use of heat pumps to heat water instead of electric heaters is a way to reduce energy consumption and consequently greenhouse gas emissions. In this context, carbon dioxide (CO2 or R744) as a refrigerant fluid has drawn the attention of several researchers in the refrigeration field. Several works in the literature evaluated the performance of the heat pump, economic performance, energy performance, exergy performance, influence of the geometry in the solar evaporator, but no work presents the behavior of the pressure in the evaporator. In this context, this paper presents a mathematical model for the heat pump evaporator (DX-SAHP) that evaluates the behavior of the pressure in the evaporator when it is not operating but exposed to the sun and the impacts of these pressures on the structural integrity of the components, considering an amount of CO2 mass trapped inside the evaporator varying between 8% and 12%. The meteorological data for solving the mathematical model were taken from INMET website for the day with highest solar radiation in 2022. The maximum R744 pressure for 12% mass inside the evaporator was around 10MPa whereas the maximum work pressure recommended by tube manufacture is 13.2MPa.
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICA
local.publisher.initialsUFMG

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
STUDY ON THE MAXIMUM PRESSURES OF A SOLAR-ASSISTED R744 - PDFA.pdf
Tamanho:
1.67 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.07 KB
Formato:
Plain Text
Descrição: