Intermittent suctioning for patients under artificial ventilation: a digital model study

dc.creatorFabiano V. O. C. Médice
dc.creatorManoel Carlos Barbosa Pereira
dc.creatorHenrique Resende Martins
dc.creatorAlcendino C. Jardim Neto
dc.date.accessioned2025-05-23T13:21:47Z
dc.date.accessioned2025-09-09T00:52:22Z
dc.date.available2025-05-23T13:21:47Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/1843/82473
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofXXVII Brazilian Congress on Biomedical Engineering (CBEB 2020)
dc.rightsAcesso Restrito
dc.subjectRespiração Artificial DeCS
dc.subject.otherTracheal pressures during open suctioning, Endotracheal suctioning of mechanically ventilated patients with artificial airways
dc.subject.otherMean lung pressure during adult high-frequency oscillatory ventilation, Humidification of base flow gas during adult high-frequency oscillatory ventilation
dc.titleIntermittent suctioning for patients under artificial ventilation: a digital model study
dc.typeArtigo de evento
local.description.resumoEndotracheal Suctioning is a clinical resource commonly used for the bronchial hygiene of patients under artificial ventilation. This work aims to propose a new procedure to avoid damage to the patient during this process. Considering the importance of assessing the impact of the mechanical ventilation-suctioning interaction on the respiratory system, one of the objectives of this work is to validate a computational model of a closed tracheal suctioning system. For that, the pressures, obtained by the model, were compared to those resulting from aspiration in a physical lung model. Combinations of catheter and orotracheal tube sizes, as well as ventilatory and suctioning pressures, were used. The difference between the alveolar pressures obtained with the computational and physical models was not greater than 0.3 cmH2O; with the correlation between the signals higher than 0.999. Therefore, the computational model was considered adequate for the alveolar mechanical representation in the proposed condition. With the validated digital model and aiming to obtain less loss of volume and alveolar pressure of the patient model, an intermittent suctioning with parameters of 4 patients was implemented (one healthy, one with a restrictive disease, one with obstructive disease and one critical with both disorders). When comparing normal and intermittent suctioning, there was an improvement in the mean alveolar pressure and a decrease in maximum pressure drop during suctioning in patients.
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA ELÉTRICA
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA ELETRÔNICA
local.publisher.initialsUFMG
local.url.externahttps://link.springer.com/chapter/10.1007/978-3-030-70601-2_130