Quantification of Glyphosate and AMPA by HPLC-ICP-MS/MS and HPLC-DAD: A Comparative Study
| dc.creator | Emanuella Mesquita Pimenta | |
| dc.creator | Fabio Ferreira da Silva | |
| dc.creator | Érica Soares Barbosa | |
| dc.creator | Ane Patrícia Cacique | |
| dc.creator | Douglas Lopes Cassimiro | |
| dc.creator | Gevany Paulino de Pinho | |
| dc.creator | Flaviano Oliveira Silvério | |
| dc.date.accessioned | 2022-04-06T21:53:08Z | |
| dc.date.accessioned | 2025-09-08T23:03:18Z | |
| dc.date.available | 2022-04-06T21:53:08Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Neste trabalho, a metodologia de determinação direta de glifosato e aminometilfosfônico ácido (AMPA) por cromatografia líquida de alta eficiência (HPLC) usando acoplamento indutivo plasma com espectrômetro de massa triplo quadrupolo (ICP-MS/MS) foi comparado com o método convencional usando detector de arranjo de diodos (HPLC-DAD). Ambos os métodos foram seletivos, mas a análise cromatográfica usando ICP-MS/MS como detector foi quatro vezes mais rápida que DAD. A metodologia usando ICP-MS/MS como detector foi linear de 27 a 218 μg L-1, enquanto por pelo método convencional foi de 1 a 8 mg L-1. Limites de detecção do glifosato alcançados com os métodos HPLC-ICP-MS/MS e HPLC-DAD foram 8,2 e 300 μg L-1, respectivamente. O a determinação direta usando ICP-MS/MS como detector mostrou um número menor de estágios na amostra preparação, pois não precisou da etapa de derivatização. Sete amostras reais foram analisadas por HPLC-ICP-MS/MS e os resultados mostraram que esses analitos não foram detectados. | |
| dc.format.mimetype | ||
| dc.identifier.doi | https://doi.org/10.21577/0103-5053.20190175 | |
| dc.identifier.issn | 0103-5053 | |
| dc.identifier.uri | https://hdl.handle.net/1843/40851 | |
| dc.language | eng | |
| dc.publisher | Universidade Federal de Minas Gerais | |
| dc.relation.ispartof | Journal of the brazilian chemical society | |
| dc.rights | Acesso Aberto | |
| dc.subject | Ácido aminometilfosfônico | |
| dc.subject | Especiação | |
| dc.subject | Sistema de detecção | |
| dc.subject | N-(fosfonometil)glicina | |
| dc.title | Quantification of Glyphosate and AMPA by HPLC-ICP-MS/MS and HPLC-DAD: A Comparative Study | |
| dc.title.alternative | Quantificação de Glifosato e AMPA por HPLC-ICP-MS/MS e HPLC-DAD: Um estudo comparativo | |
| dc.type | Artigo de periódico | |
| local.citation.epage | 304 | |
| local.citation.issue | .2 | |
| local.citation.spage | 298 | |
| local.citation.volume | .31 | |
| local.description.resumo | In this work, the direct determination methodology of glyphosate and aminomethylphosphonic acid (AMPA) by high performance liquid chromatography (HPLC) using inductively coupled plasma with triple quadrupole mass spectrometer (ICP-MS/MS) was compared with the conventional method using diode array detector (HPLC-DAD). Both methods were selective, but the chromatographic analysis using ICP-MS/MS as detector was four times faster than DAD. The methodology using ICP-MS/MS as detector was linear from 27 to 218 μg L-1, while by the conventional method it was 1 to 8 mg L-1. Detection limits of the glyphosate achieved with the HPLC-ICP-MS/MS and HPLC-DAD methods were 8.2 and 300 μg L-1, respectively. The direct determination using ICP-MS/MS as detector showed a lower number of stages in sample preparation because it did not need the derivatization step. Seven real samples were analyzed by HPLC-ICP-MS/MS and the results showed that these analytes were not detected. | |
| local.publisher.country | Brasil | |
| local.publisher.department | ICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS | |
| local.publisher.initials | UFMG | |
| local.url.externa | https://www.scielo.br/j/jbchs/a/QGrXkbD7gH4bLZGNYxvZzpJ/abstract/?lang=en |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- 2019_Quantification of glyphosate and ampa by hplc-icp-ms-ms and hplc-dad- a comparative study.pdf
- Tamanho:
- 250.04 KB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1