Quantification of Glyphosate and AMPA by HPLC-ICP-MS/MS and HPLC-DAD: A Comparative Study

dc.creatorEmanuella Mesquita Pimenta
dc.creatorFabio Ferreira da Silva
dc.creatorÉrica Soares Barbosa
dc.creatorAne Patrícia Cacique
dc.creatorDouglas Lopes Cassimiro
dc.creatorGevany Paulino de Pinho
dc.creatorFlaviano Oliveira Silvério
dc.date.accessioned2022-04-06T21:53:08Z
dc.date.accessioned2025-09-08T23:03:18Z
dc.date.available2022-04-06T21:53:08Z
dc.date.issued2019
dc.description.abstractNeste trabalho, a metodologia de determinação direta de glifosato e aminometilfosfônico ácido (AMPA) por cromatografia líquida de alta eficiência (HPLC) usando acoplamento indutivo plasma com espectrômetro de massa triplo quadrupolo (ICP-MS/MS) foi comparado com o método convencional usando detector de arranjo de diodos (HPLC-DAD). Ambos os métodos foram seletivos, mas a análise cromatográfica usando ICP-MS/MS como detector foi quatro vezes mais rápida que DAD. A metodologia usando ICP-MS/MS como detector foi linear de 27 a 218 μg L-1, enquanto por pelo método convencional foi de 1 a 8 mg L-1. Limites de detecção do glifosato alcançados com os métodos HPLC-ICP-MS/MS e HPLC-DAD foram 8,2 e 300 μg L-1, respectivamente. O a determinação direta usando ICP-MS/MS como detector mostrou um número menor de estágios na amostra preparação, pois não precisou da etapa de derivatização. Sete amostras reais foram analisadas por HPLC-ICP-MS/MS e os resultados mostraram que esses analitos não foram detectados.
dc.format.mimetypepdf
dc.identifier.doihttps://doi.org/10.21577/0103-5053.20190175
dc.identifier.issn0103-5053
dc.identifier.urihttps://hdl.handle.net/1843/40851
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofJournal of the brazilian chemical society
dc.rightsAcesso Aberto
dc.subjectÁcido aminometilfosfônico
dc.subjectEspeciação
dc.subjectSistema de detecção
dc.subjectN-(fosfonometil)glicina
dc.titleQuantification of Glyphosate and AMPA by HPLC-ICP-MS/MS and HPLC-DAD: A Comparative Study
dc.title.alternativeQuantificação de Glifosato e AMPA por HPLC-ICP-MS/MS e HPLC-DAD: Um estudo comparativo
dc.typeArtigo de periódico
local.citation.epage304
local.citation.issue.2
local.citation.spage298
local.citation.volume.31
local.description.resumoIn this work, the direct determination methodology of glyphosate and aminomethylphosphonic acid (AMPA) by high performance liquid chromatography (HPLC) using inductively coupled plasma with triple quadrupole mass spectrometer (ICP-MS/MS) was compared with the conventional method using diode array detector (HPLC-DAD). Both methods were selective, but the chromatographic analysis using ICP-MS/MS as detector was four times faster than DAD. The methodology using ICP-MS/MS as detector was linear from 27 to 218 μg L-1, while by the conventional method it was 1 to 8 mg L-1. Detection limits of the glyphosate achieved with the HPLC-ICP-MS/MS and HPLC-DAD methods were 8.2 and 300 μg L-1, respectively. The direct determination using ICP-MS/MS as detector showed a lower number of stages in sample preparation because it did not need the derivatization step. Seven real samples were analyzed by HPLC-ICP-MS/MS and the results showed that these analytes were not detected.
local.publisher.countryBrasil
local.publisher.departmentICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS
local.publisher.initialsUFMG
local.url.externahttps://www.scielo.br/j/jbchs/a/QGrXkbD7gH4bLZGNYxvZzpJ/abstract/?lang=en

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2019_Quantification of glyphosate and ampa by hplc-icp-ms-ms and hplc-dad- a comparative study.pdf
Tamanho:
250.04 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: