Biomechanical behavior of tooth-implant supported prostheses with different implant connections : a nonlinear finite element analysis

dc.creatorGustavo Assis de Paula
dc.creatorGuilherme Carvalho Silva
dc.creatorÊnio Lacerda Vilaça
dc.creatorTulimar Machado Cornacchia
dc.creatorCláudia Silami de Magalhães
dc.creatorAllyson Nogueira Moreira
dc.date.accessioned2022-08-16T18:11:00Z
dc.date.accessioned2025-09-08T23:20:52Z
dc.date.available2022-08-16T18:11:00Z
dc.date.issued2018-06
dc.format.mimetypepdf
dc.identifier.doi10.1097/ID.0000000000000737
dc.identifier.issn10566163
dc.identifier.urihttps://hdl.handle.net/1843/44285
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofImplant Dentistry
dc.rightsAcesso Restrito
dc.subjectDental implants
dc.subjectDental prosthesis
dc.subjectBiomechanical phenomena
dc.subject.otherBiomechanics
dc.subject.otherDental prosthesis
dc.subject.otherDental implant
dc.titleBiomechanical behavior of tooth-implant supported prostheses with different implant connections : a nonlinear finite element analysis
dc.typeArtigo de periódico
local.citation.epage302
local.citation.issue2
local.citation.spage294
local.citation.volume27
local.description.resumoPurpose: Biomechanical behavior of tooth-implant-supported prostheses (TISPs) with external and internal implants was compared. Materials and methods: Two 3-D models of TISP were designed by varying the implant: external (Model EH) and internal hexagons (Model IH). After loading, von Mises stresses were obtained in implants, abutments, and screws. Principal maximum (σmax) and minimum (σmin) stresses were analyzed in periodontal ligament (PL), alveolar bone, and periimplant bone. Results: Model IH showed lower stress peaks in axial loading in the implant and in the screw but higher in abutment. In oblique loading, Model IH had lower stresses in the implant, but higher in the abutment and in the screw. In the σmax analysis for axial and oblique loads, stress peaks in Model IH were lower in PL, alveolar bone, and periimplant bone. In the σmin analysis for axial load, stress peaks in Model IH were lower in PL, but higher in alveolar bone and in periimplant bone. In oblique load, Model IH showed lower stress peaks in PL and alveolar bone, but higher stress peaks in periimplant bone. Conclusions: TISPs with IH implants do present lower risk of biomechanical failure.
local.publisher.countryBrasil
local.publisher.departmentFAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA
local.publisher.departmentFAO - DEPARTAMENTO DE ODONTOLOGIA SOCIAL E PREVENTIVA
local.publisher.initialsUFMG
local.url.externahttps://journals.lww.com/implantdent/Fulltext/2018/06000/Biomechanical_Behavior_of_Tooth_Implant_Supported.9.aspx

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: