Efficient extraction method using magnetic carbon nanotubes to analyze cocaine and benzoylecgonine in breast milk by GC/MS
| dc.creator | Rosimeire Resende dos Santos | |
| dc.creator | Maria José Nunes Paiva | |
| dc.creator | Júlio César Veloso | |
| dc.creator | Philippe Serp | |
| dc.creator | Zenilda de Lourdes Cardeal | |
| dc.creator | Helvécio Costa Menezes | |
| dc.date.accessioned | 2023-01-06T13:32:28Z | |
| dc.date.accessioned | 2025-09-08T23:42:28Z | |
| dc.date.available | 2023-01-06T13:32:28Z | |
| dc.date.issued | 2017 | |
| dc.identifier.doi | https://doi.org/10.4155/bio-2017-0140 | |
| dc.identifier.issn | 1757-6180 | |
| dc.identifier.uri | https://hdl.handle.net/1843/48757 | |
| dc.language | eng | |
| dc.publisher | Universidade Federal de Minas Gerais | |
| dc.relation.ispartof | Bioanalysis | |
| dc.rights | Acesso Restrito | |
| dc.subject | Amamentação | |
| dc.subject | Leite humano | |
| dc.subject | Análise | |
| dc.subject | Cocaína | |
| dc.subject | Cromatografia de gás | |
| dc.subject | Espectrometria de massa | |
| dc.subject | Nanotubos de carbono | |
| dc.subject.other | Enzoylecgonine | |
| dc.subject.other | Breast milk | |
| dc.subject.other | Cocaine | |
| dc.subject.other | GC/MS | |
| dc.subject.other | Gas chromatography–mass spectrometry | |
| dc.subject.other | Magnetic carbon nanotubes | |
| dc.title | Efficient extraction method using magnetic carbon nanotubes to analyze cocaine and benzoylecgonine in breast milk by GC/MS | |
| dc.type | Artigo de periódico | |
| local.citation.epage | 1666 | |
| local.citation.issue | 21 | |
| local.citation.spage | 1655 | |
| local.citation.volume | 9 | |
| local.description.resumo | Aim: The increasing use of cocaine (COC) during breastfeeding has led to growing concern about exposure of infants. Therefore, to study this exposure, a new method to analyze COC and benzoylecgonine in breast milk was developed. Methodology: A new extraction method was used for the first time to analyze COC and its major metabolite, benzoylecgonine, in breast milk using magnetic carbon nanotubes partially doped with nitrogen. Results: The calibration curves were linear in the range 5.0–180.0 ng ml-1. The limit of quantification was 5.0 ng ml-1. Coefficients of variation were between 3.2 and 13.9%. Recovery was between 89.6 and 99.2%. Conclusion: The proposed method is simple, efficient and suitable to determine analytes in breast milk. | |
| local.identifier.orcid | https://orcid.org/0000-0003-1383-6299 | |
| local.identifier.orcid | https://orcid.org/0000-0002-5759-612X | |
| local.publisher.country | Brasil | |
| local.publisher.department | FAR - DEPARTAMENTO DE ANÁLISES CLÍNICAS E TOXICOLÓGICAS | |
| local.publisher.department | ICX - DEPARTAMENTO DE QUÍMICA | |
| local.publisher.initials | UFMG | |
| local.url.externa | https://www.future-science.com/doi/abs/10.4155/bio-2017-0140?journalCode=bio |
Arquivos
Licença do pacote