Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/41267
Type: Artigo de Periódico
Title: Activity monitor placed at the nonparetic ankle is accurate in measuring step counts during community walking in poststroke Individuals: a validation study
Authors: Noémie Duclos
Larissa Tavares Aguiar
Rachid Aissaoui
Christina Danielli Coelho de Morais Faria
Sylvie Nadeau
Cyril Duclos
Abstract: Background: Different environmental factors may affect the accuracy of step-count activity monitors (AM). However, the validation conditions for AM accuracy largely differ from ecological environments. Objectives: To assess and compare the accuracy of AM in counting steps among poststroke individuals: during different locomotor tasks, with AM placed at the nonparetic ankle or hip, and when walking in a laboratory or inside a mall. Design: Validation study. Settings: Laboratory and community settings. Participants: Twenty persons with chronic hemiparesis, independent walkers. Methods: First session: participants performed level walking (6-minute walk test [6MWT]), ramps, and stairs in the laboratory with AM placed at the nonparetic ankle and hip. Second session: participants walked a mall circuit, including the three tasks, with AM placed at the nonparetic ankle. The sessions were video recorded. Main outcome measurements: Absolute difference between the steps counted by AM and the steps viewed on the video recordings (errors, %); occurrence of errors greater than 10%. Results: Median errors were similar for the 6MWT (0.86 [0.22, 7.70]%), ramps (2.17 [0.89, 9.61]%), and stairs (8.33 [2.65, 19.22]%) with AM at the ankle. Step-count error was lower when AM was placed at the ankle (8.33 [2.65, 19.22]%) than at the hip (9.26 [3.25, 42.63]%, P = .03). The greatest errors were observed among the slowest participants (≤0.4 m/s) on ramps and stairs, whereas some faster participants (>1 m/s) experienced the greatest error during the 6MWT. Median error was slightly increased in the mall circuit (2.67 [0.61, 12.54]%) compared with the 6MWT (0.50 [0.24, 6.79]%, P = .04), with more participants showing errors >10% during the circuit (7 vs 2, P = .05). Conclusions: Step counts are accurately measured with AM placed at the nonparetic ankle in laboratory and community settings. Accuracy can be altered by stairs and ramps among the slowest walkers and by prolonged walking tasks among faster walkers. Level of evidence: III.
Subject: Caminhada - Medição
Acidente vascular cerebral
Avaliação
language: eng
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: EEF - DEPARTAMENTO DE FISIOTERAPIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1002/pmrj.12080
URI: http://hdl.handle.net/1843/41267
Issue Date: 2019
metadata.dc.url.externa: https://onlinelibrary.wiley.com/doi/10.1002/pmrj.12080
metadata.dc.relation.ispartof: PM&R
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.