dc.description.abstractProver controle adequado e de baixo custo é uma importante etapa no processo de uso da bomba de calor de expansão direta assistida por energia solar (DX-SAHP) em substituição aos chuveiros elétricos nas residências brasileiras. Neste sentido, projetar um controlador de baixo custo para regular a temperatura de água quente em 60°C (armazenamento) e 45°C (consumo direto) é o primeiro objetivo deste trabalho. Testes experimentais mostraram a capacidade do controlador em manter, em diferentes condições ambientais e de operação, a temperatura da água quente no valor desejado. O segundo objetivo deste estudo é avaliar a área de abertura do dispositivo de expansão. Os efeitos da manutenção de uma abertura fixa para o dispositivo de expansão no funcionamento e no desempenho do sistema, sobretudo os de pequeno porte, não são bem conhecidos. Neste contexto, é realizada uma análise experimental da influência da abertura do dispositivo de expansão no desempenho de uma CO2 DX-SAHP. Experimentos foram realizados com radiações próximas a 48 W/m² e 715 W/m², resultando em coeficiente de performance (COP) iguais a 2,21 e 2,58 respectivamente. Observou-se que a abertura do dispositivo de expansão para a qual obtevese o COP máximo foi similar independente da radiação solar. Em consequência, para uma CO2 DX-SAHP de pequeno porte, operando em uma configuração de ciclo básico (na qual o dispositivo de expansão é utilizado para controlar a pressão de alta ótima e consequentemente o COP), um sistema embarcado de baixo custo para controle da temperatura de água e um dispositivo de expansão estático podem proporcionar um controle adequado. Finalmente, o terceiro objetivo deste estudo é avaliar os efeitos de uma variação repentina da radiação solar no grau de superaquecimento. Dados experimentais foram utilizados para validação do modelo. Após validação, o modelo foi utilizado para realizar diversas simulações. Os resultados mostraram que uma pequena variação na radiação solar produz uma variação significativa no grau de superaquecimento, demandando uma ação imediata do dispositivo de expansão. Conclui-se então, que uma válvula de expansão eletrônica poderia ser o dispositivo de expansão mais indicado para regular a vazão mássica de CO2 na entrada do evaporador. Ressaltando-se que ainda, a operação em continuo regime transiente em algumas estações do ano reforça a indicação da válvula eletrônica.pt_BR
dc.description.resumoProviding adequate and low-cost control is an important step in the use of direct expansion solar assisted heat pump (DX-SAHP) in replacement of the electric showers in the Brazilian residences. In that way, design a low-cost controller to regulate the hot water temperature in 60°C (to storage) and 45°C (to direct consumption) is the first goal of this study. Experimental tests demonstrated the capacity of the control system to keep hot water in the correct temperature in different environment and system conditions. The second goal of this study is to evaluate the expansion valve opening. The impact of a fixed aperture in the functioning and on the performance of these systems is not well known, especially for small-size systems. In this context, it is presented an experimental analysis of the influence of the expansion valve opening on the performance of a carbon dioxide (CO2) DX-SAHP. Experimental tests were carried out considering solar radiations about 48 W/m² and 715 W/m² in which the coefficient of performance (COP) observed were 2.21 and 2.58, respectively. The value of the expansion device opening that leads to the maximum COP was similar, regardless the solar radiation. In consequence, for a small CO2 DX-SAHP, using a basic cycle configuration (where the expansion device is used to control the optimum high pressure and consequently the COP), a low-cost embedded system water temperature control and a static expansion device would be suitable for proper control. Finally, the third goal of this study is to evaluate the effects of the sudden variations in the solar radiation on the superheat. The mathematical model was validated using experimental data and employed to perform several simulations. The results obtained with the mathematical model revealed that a small variation of the solar radiation leads to a significant variation in the superheat, therefore requiring an immediate action of the expansion device. In conclusion, an electronic expansion valve would be better suited to meet the needs of rapid interventions on the mass flow rate at the evaporator inlet and also the DX-SAHP could operate in a continuous transient condition in some seasons.pt_BR
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Geraispt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICApt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Mecanicapt_BR
dc.publisher.initialsUFMGpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectHeat pumppt_BR
dc.subjectSolar assistedpt_BR
dc.subjectCO2pt_BR
dc.subjectDynamic responsept_BR
dc.subjectDirect expansionpt_BR
dc.subject.otherEngenharia mecânicapt_BR
dc.subject.otherDióxido de carbonopt_BR
dc.subject.otherEnergia solarpt_BR
dc.subject.otherBombas de calorpt_BR
dc.titleExperimental and theoretical study of the dynamic response of a small size CO2 direct expansion solar assisted heat pumppt_BR
dc.title.alternativeEstudo experimental e teórico da resposta dinâmica de uma bomba de calor solar assistida por expansão direta de CO2 de pequeno portept_BR
dc.typeTesept_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-2446-0373pt_BR
Appears in Collections:Teses de Doutorado

Files in This Item:
File Description SizeFormat 
Tese - Tiago de Freitas Paulino - Versao Final.pdf4.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.