Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/48001
Tipo: Artigo de Periódico
Título: Microtensile bond strength of composite resin and glass ionomer cement with total-etching or self-etching universal adhesive
Autor(es): Laís Sant'ana .Munari
Alberto Nogueira da Gama Antunes
Débora Drummond Hauss Monteiro
Allyson Nogueira Moreira
Hugo Henriques Alvim
Cláudia Silami Magalhães
Resumo: Purpose To assess the effect of acid etching (AE) and adhesive systems on the microtensile bond strength of conventional glass ionomer cement (GIC) and a nanofilled composite resin. Materials and methods Specimens of conventional GIC (RIVA, Self-cure, SDI) were prepared in a bipartite Teflon mold and randomly assigned (n=12) to G1- GIC+Single Bond 2 (SB2) (3M-ESPE); G2- GIC+Acid etching (AE) (37% phosphoric acid, Condac, FGM) + SB2; G3- GIC+Single Bond Universal (SBU) (3M-ESPE); and G4- GIC+AE+SBU. The adhesive systems and the composite (Filtek Z350XT, 3M-ESPE) were inserted into the mold. After 7 days stored in a humid environment, the specimens were sectioned into five slices (Isomet 1000, Buehler). Hourglass slices were trimmed and subjected to microtensile bond strength testing (BISCO®; Schaumburg, USA) with 0.5 mm/min crosshead speed. Data were analyzed by two-way ANOVA and the Tukey test (SPSS 17.0, α=5%). Results The microtensile bond strength (MPa) means (standard deviation) were G1=9.46(3.79), G2=6.27(3.21), G3=9.35(3.91), and G4=10.13(3.53). G2 differed significantly from the other groups (p<0.001). G1, G3 and G4 were not significantly different from each other (p>0.05). There were 83% mixed fractures, 9.5% cohesive and 7.5% adhesive. Conclusion GIC etching promoted higher microtensile bond strength with universal adhesive than with a total-etch adhesive system. Acid etching is not necessary to enhance the universal adhesive bond strength and negatively affected the bond strength of the total-etch adhesive system. Without etching the GIC, there is no difference in microtensile bond strength between the adhesive systems
Assunto: Acids
Glass ionomer cements
Composite resins
Traction
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: FAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA
Tipo de Acesso: Acesso Restrito
Identificador DOI: https://doi.org/10.1016/j.ijadhadh.2017.12.013
URI: http://hdl.handle.net/1843/48001
Data do documento: Abr-2018
metadata.dc.url.externa: https://www.sciencedirect.com/science/article/pii/S0143749617302300
metadata.dc.relation.ispartof: International Journal of Adhesion and Adhesives
Aparece nas coleções:Artigo de Periódico

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.