Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/51127
Type: Dissertação
Title: Estudo numérico dos conectores Crestbond em pilares mistos esbeltos
Other Titles: Numerical study of Crestbond connectors applied in concrete-filled steel tube columns
Authors: Ariany Cardoso Pereira
First Advisor: Rodrigo Barreto Caldas
First Referee: Ana Lydia Reis de Castro e Silva
Second Referee: Renata Gomes Lanna da Silva
Abstract: Os pilares mistos preenchidos com concreto (PMPC) podem ter a seção transversal classificada em função da esbeltez local do perfil tubular como sendo: esbelta, semicompacta ou compacta. Apesar de serem encontrados modelos de cálculo para a determinação da força axial resistente, a transferência de forças vindas das vigas conectadas nesses pilares ainda dispõe de poucas soluções e estudos. Este trabalho tem como objetivo apresentar o processo de desenvolvimento e validação de um modelo numérico para simular o comportamento dos conectores Crestbond aplicados a (PMPC) de seção tubular esbelta. Essa é uma nova aplicação para conectores deste tipo e para tanto foi realizado um conjunto de experimentos com o objetivo de ampliar o banco de dados utilizado na validação e aplicação de um modelo numérico desenvolvido em trabalhos anteriores. Após definido o modelo numérico, que pode ser utilizado para o estudo e projeto da transferência de força em pilares de seção esbelta utilizando conectores em chapa conhecidos como composite dowels, realizou-se um estudo de sensibilidade dos parâmetros mais relevantes. Por fim, verificou-se que a esbeltez da seção é o que governa o comportamento da conexão, independentemente dos parâmetros que se está avaliando, e que as características geométricas e mecânicas do conector são pontos fundamentais a serem observados na definição de um conector de cisalhamento eficiente para aplicação em pilares mistos preenchidos com concreto.
Abstract: Concrete-filled steel tube (CFST) columns cross section can be classified according to the local slenderness of the steel tubular profile as slender, semi-compact or compact. Although the analytical models determine the axial resistance force, there is still little research and solutions available about the force transfer mechanisms between CFST columns and beams. This study aims to present the development and validation of a numerical model to simulate the behavior of Crestbond connectors applied to slender CFST columns. For this purpose, experiments were carried out to expand the database used for the validation and application of a numerical model developed in previous works. After defining the numerical model, which can be used for the study and design for force transfer in slender columns with sheet metal connectors, known as composite dowels, a sensitivity study of the most relevant parameters was carried out. Finally, it was found that the slenderness of section governed the connection's behavior, regardless of the parameters being evaluated, and that the geometric and mechanical characteristics of the connector are fundamental points to be observed in the definition of a most efficient shear connector for application in concrete filled stel tube columns.
Subject: Engenharia de estruturas
Conectores de cisalhamento
Análise numérica
Colunas de concreto
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ENG - DEPARTAMENTO DE ENGENHARIA ESTRUTURAS
metadata.dc.publisher.program: Programa de Pós-Graduação em Engenharia de Estruturas
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/51127
Issue Date: 28-Feb-2020
Appears in Collections:Dissertações de Mestrado

Files in This Item:
File Description SizeFormat 
ARIANY_CARDOSO_PEREIRA_DISSERTAÇÃO_MESTRADO_versão_REPOSITÓRIO-revisado.pdfrevisão 30-12-20226.18 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.