Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/55800
Full metadata record
DC FieldValueLanguage
dc.creatorMaria Letícia de Mirandamatipt_BR
dc.creatorNatalia Rocha Guimarãespt_BR
dc.creatorPaula Prazeres Magalhãespt_BR
dc.creatorLuiz de Macêdo Fariaspt_BR
dc.creatorAdriana Cristina de Oliveirapt_BR
dc.date.accessioned2023-07-04T22:49:21Z-
dc.date.available2023-07-04T22:49:21Z-
dc.date.issued2019-
dc.citation.volume27pt_BR
dc.identifier.doihttps://doi.org/10.1590/1518-8345.3101.3211pt_BR
dc.identifier.issn1518-8345pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/55800-
dc.description.abstractObjetivo: avaliar a potencial contaminação do detergente enzimático a partir de seu reuso e identificar o perfil microbiológico na solução utilizada na limpeza de aparelhos endoscópicos gastrointestinais. Método: estudo transversal realizado a partir da análise microbiológica de 76 alíquotas de 19 diferentes soluções de detergente enzimático utilizadas na limpeza de aparelhos endoscópicos. As alíquotas foram homogeneizadas, submetidas a filtração em membrana Millipore® 0,45μm e a identificação presuntiva dos microrganismos foi realizada por métodos bioquímico-fisiológico conforme grupos bacterianos específicos previamente estabelecidos e que apresentam importância clínica e epidemiológica. Resultados: Os valores médios, assim como o desvio-padrão e a mediana, da carga microbiana do detergente enzimático foram crescentes à medida que a solução foi reutilizada. Houve diferença significativa entre as médias de após primeiro uso e após quinto reuso. Foram identificados 97 microrganismos, com predomínio dos gêneros Staphylococcus coagulase negativa, Pseudomonasspp., Klebsiella spp., Enterobacter spp., e da espécie Escherichia coli. Conclusão: O reuso da solução de detergente enzimático constitui um risco ao processamento seguro dos aparelhos endoscópios, evidenciado pela sua contaminação com microrganismos que apresentam potencial patogênico, uma vez que o detergente enzimático não possui propriedade bactericida e pode contribuir como fonte importante para surtos em pacientes submetidos a tais procedimentos.pt_BR
dc.description.resumoObjective: to evaluate the potential contamination of enzymatic detergent from its reuse and to identify the microbiological profile in the solution used to clean gastrointestinal endoscopic devices. Method: cross-sectional study based on microbiological analysis of 76 aliquots of 19 different enzymatic detergent solutions used to clean endoscopic devices. The aliquots were homogenized, subjected to Millipore® 0.45 µm membrane filtration and the presumptive identification of microorganisms was performed by biochemical-physiological methods according to previously established specific bacterial groups that are of clinical and epidemiological relevance. Results: the mean values, as well as the standard deviation and the median, of the enzymatic detergent microbial load increased as the solution was reused. There was a significant difference between the means of after first use and after fifth reuse. A total of 97 microorganisms were identified, with predominance of the coagulase-negative Staphylococcus, Pseudomonas spp., Klebsiella spp., Enterobacter spp. genus, and Escherichia coli species. Conclusion: the reuse of the enzymatic detergent solution is a risk to the safe processing of endoscopic devices, evidenced by its contamination with pathogenic potential microorganisms, since the enzymatic detergent has no bactericidal property and can contribute as an important source for outbreaks in patients under such procedures.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentENF - DEPARTAMENTO DE ENFERMAGEM BÁSICApt_BR
dc.publisher.departmentICB - DEPARTAMENTO DE MICROBIOLOGIApt_BR
dc.publisher.departmentICB - INSTITUTO DE CIÊNCIAS BIOLOGICASpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofRevista Latino-Americana de Enfermagem-
dc.rightsAcesso Abertopt_BR
dc.subjectPatient safetypt_BR
dc.subjectEndoscopespt_BR
dc.subjectDetergentspt_BR
dc.subjectSanitizing productspt_BR
dc.subjectMicrobiologypt_BR
dc.subjectInfection controlpt_BR
dc.subject.otherSegurança do Pacientept_BR
dc.subject.otherEndoscópiospt_BR
dc.subject.otherDetergentespt_BR
dc.subject.otherSaneantespt_BR
dc.subject.otherMicrobiologiapt_BR
dc.subject.otherControle de Infecçõespt_BR
dc.titleEnzymatic detergent reuse in gastroscope processing: a potential source of microorganism transmissionpt_BR
dc.title.alternativeReutilização do detergente enzimático no processamento de gastroscópios: uma potencial fonte de transmissão de microrganismospt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.scielo.br/j/rlae/a/HLvtRPBKRCCwmF3zz8JZVsw/abstract/?lang=enpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-9272-641Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-9859-5895pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-6519-8490pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7462-767Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4821-6068pt_BR
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.