Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/56612
Type: Artigo de Periódico
Title: O volume de fluxo e a velocidade de pico sistólico ao ultrassom vascular com doppler intraoperatório como preditores de perviedade precoce na fístula arteriovenosa autógena para hemodiálise
Other Titles: Intraoperative vascular Doppler ultrasound blood flow and peak systolic velocity predict early patency in hemodialysis arteriovenous fistula
Authors: Guilherme Decastro-santos
Gabriella Yuka Shiomatsu
Rafaela Martins Dos Santos Oliveira
Ricardo Jayme Procópio
Túlio Pinho Navarro
Abstract: Contexto: A insuficiência renal crônica é um problema de saúde pública mundial. A hemodiálise é a principal terapia renal substitutiva. As fístulas arteriovenosas (FAV) são uma possível escolha, mas apresentam altas taxas de falência. Objetivos: Este estudo tem como objetivo avaliar a relação entre as variáveis hemodinâmicas ao ultrassom vascular com Doppler no intraoperatório e a perviedade precoce da FAV para hemodiálise. Métodos: Tratou-se de um estudo prospectivo observacional. Os pacientes consecutivos foram submetidos a FAV com ultrassonografia vascular com Doppler em intraoperatório nos dias 1, 7, 30 e 60. Eles foram divididos em grupos quanto à presença ou não de perviedade primária e secundária, e o volume de fluxo (VF) e a velocidade de pico sistólico (VPS) foram comparados. Foram realizadas curvas receiver operating characteristic (ROC), com definição de valores de VPS e VF com sensibilidade (S) e especificidade (E). Resultados: Foram analisados 47 pacientes, os quais preencheram os critérios de inclusão. Os valores de VPS e VF intraoperatório foram maiores nos pacientes com perviedade primária e secundária comparados àqueles com falência. Os seguintes valores apresentaram maiores sensibilidade e especificidade para predizer perviedade primária aos 30 dias: 106 cm/s para VPS venoso, S: 75%, E: 71,4%; e 290,5 mL/min para VF arterial, S: 80,6%, E: 85,7%. Para perviedade secundária aos 30 dias, foram observados: 106 cm/s para VPS arterial, S: 72,7%, E: 100%; e 230 mL/min para VF venoso, com S: 86,4%, E: 100%. Para a perviedade primária no 60º dia, foram observados: 106 cm/s para VPS venoso, S: 74,4%, E: 62,5%; e 290,5 mL/min para VF arterial, S: 80%, E: 75%. Conclusões: A velocidade de pico sistólico e o VF ao ultrassom vascular com Doppler intraoperatório são preditores de perviedade precoce na FAV para hemodiálise.
Abstract: Background: Chronic kidney disease is a major public health problem. Hemodialysis is the most common renal replacement therapy. Arteriovenous fistulas (AVF) are a possible access option, but early failure rates remain high. Objectives: to investigate the value of intraoperative vascular Doppler ultrasound for predicting early AVF patency. Methods: Prospective observational study. Consecutive patients undergoing AVF were assessed with vascular Doppler ultrasonography intraoperatively and on days 1, 7, 30, and 60. Patients were divided into groups according to presence or absence of primary and secondary patency. Blood flow (BF) and peak systolic velocity (PSV) were compared. ROC curves were plotted and used to define the PSV and BF values that yielded greatest sensitivity (Sens) and specificity (Spec). Results: 47 patients met the inclusion criteria and were analyzed. Higher intraoperative PSV and BF values were observed in patients who had primary and secondary patency than in patients with access failure. The values with greatest sensitivity and specificity for predicting 30-day primary patency were 106 cm/s for venous PSV (Sens: 75% and Spec: 71.4%) and 290.5 ml/min for arterial blood flow (Sens: 80.6% and Spec 85.7%). Values for 30-day secondary patency were 106 cm/s for arterial PSV (Sens: 72.7%, Spec: 100%) and 230 ml/min for venous blood flow (Sens: 86.4%, Spec100%). Values for 60-day primary patency were 106 cm/s for venous PSV (Sens: 74.4%, Spec: 62.5%) and 290.5 ml/min for arterial blood flow (Sens: 80%, Spec: 75%). Conclusions: Peak systolic velocity and blood flow measured using intraoperative vascular Doppler ultrasound can predict early patency of hemodialysis arteriovenous fistulas.
Subject: Fístula arteriovenosa
Ultrassom
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: MED - DEPARTAMENTO DE CIRURGIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1590/1677-5449.210098
URI: http://hdl.handle.net/1843/56612
Issue Date: 2021
metadata.dc.url.externa: https://www.scielo.br/j/jvb/a/9HqbzJxhHJkcT4zmpXcVbRS/?lang=pt
metadata.dc.relation.ispartof: Jornal Vascular Brasileiro
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.