dc.description.abstract | The objective of this work is evaluate and improve the energy efficiency of a higher education building, retrofitting the electrical lighting system, reforming the electrical system and complying to NBR ISO/CIE 8595:2013, for classification A, using INI-C. The methodology involved surveying the lighting system and building plants, simulation of illuminances, classification of the current and of the proposed system and payback time estimation. It was noticed that it was necessary to meet higher levels of illuminance, and with the retrofit, lighting energy consumption can still be reduced by 28%, with a payback time of 2,26 years. | pt_BR |
dc.description.resumo | O objetivo deste trabalho é avaliar e melhorar a eficiência energética de uma edificação de ensino superior, com retrofit do sistema de iluminação elétrica, reforma do sistema elétrico e atendimento à NBR ISO/CIE 8595:2013, para classificação A, pela INI-C. A metodologia envolveu levantamento do sistema de iluminação e das plantas da edificação, simulação de iluminâncias, classificação do sistema atual e do sistema proposto e cálculo de retorno do investimento. Foi necessário atender à níveis de iluminância mais altos e, com a reforma, pode-se ainda reduzir 28% no consumo de energia para iluminação, com payback de 2,26 anos. | pt_BR |
dc.description.sponsorship | FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais | pt_BR |
dc.format.mimetype | pt_BR | |
dc.language | por | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | ARQ - DEPARTAMENTO DE TEC ARQUITETURA E URBANISMO | pt_BR |
dc.publisher.department | ARQ - ESCOLA DE ARQUITETURA | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Encontro Nacional de Tecnologia do Ambiente Construído | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Eficiência energética | pt_BR |
dc.subject | Iluminação | pt_BR |
dc.subject | INI-C | pt_BR |
dc.subject | NBR ISO/CIE 8995 | pt_BR |
dc.subject | Edificação de ensino | pt_BR |
dc.subject.other | Energia - Consumo | pt_BR |
dc.subject.other | Energia Elétrica | pt_BR |
dc.subject.other | Iluminação | pt_BR |
dc.subject.other | Ensino Superior | pt_BR |
dc.title | Sistema de iluminação do CAD 3 - análise pela INI-C para retrofit | pt_BR |
dc.title.alternative | Lighting system CAD 3 - INI-C analysis and retrofit | pt_BR |
dc.type | Artigo de Evento | pt_BR |
dc.url.externa | https://eventos.antac.org.br/index.php/entac/article/view/2152 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0002-5196-3566 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0001-5500-6387 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0002-2597-0981 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0001-5555-3647 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-0036-961X | pt_BR |
Appears in Collections: | Artigo de Evento |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Sistema de iluminação do CAD 3 - análise pela INI-C para retrofit.pdf | 534.71 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.