Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/62994
Type: Artigo de Periódico
Title: Análise das medidas eletroglotográficas da voz: padrões de normalidade para cantores por meio do programa csl da kay pentax®
Other Titles: Electroglotographic voice measurement analysis: normality standards for singers through Kay Pentax® CSL Program
Authors: Ana Clara Sotero Alves
Ana Cristina Côrtes Gama
Max de Castro Magalhães
Patrícia de Freitas Lopes Genilhú
Rafaella Cristina Oliveira
Abstract: Objetivo: Analisar as medidas de frequência fundamental, jitter eletroglotográfico, quociente de contato e periodicidade das ondas eletroglotográficas da voz de cantores em registro modal. Método: Estudo observacional de corte transversal que selecionou indivíduos de escolas de canto da região central do município de Belo Horizonte-MG. A amostra foi não probabilística, por conveniência, composta por 60 indivíduos cantores com faixa etária entre 18 e 55 anos, sendo 30 homens e 30 mulheres. Para a coleta do registro eletroglotográfico, foi utilizado o programa CSL da Kay Pentax™, model 6103, módulo Electroglottography. Os participantes foram posicionados sentados e, após a higienização da pele do pescoço com álcool 70 %, dois eletrodos foram colocados nas alas da cartilagem tireóidea no nível das pregas vocais. Posteriormente, os participantes foram orientados a emitir a vogal /a/ sustentada de forma habitual. Foram analisadas as medidas de frequência fundamental (f0), quociente de contato (QC), jitter eletroglotográfico e periodicidade da onda eletroglotográfica. Os dados foram analisados estatisticamente utilizando o Minitab 17. Resultados: Os parâmetros analisados foram estatisticamente significantes. A frequência fundamental (f0) foi maior nas mulheres (226,91 Hz) quando comparada com a dos homens (166,54 Hz). As medidas de quociente de contato e de periodicidade também foram maiores nas mulheres (40,46 % e 15,51 %, respectivamente) se comparadas às dos homens (27,45 % e 7,82, respectivamente). O parâmetro de jitter foi maior nos homens, quando comparado ao das mulheres. Conclusão: Os valores de frequência fundamental (f0), quociente de contato (QC) e periodicidade da onda foram maiores nas mulheres. O valor de jitter foi maior nos homens.
Abstract: Purpose: Analyze the measures of the fundamental frequency, electroglotographic jitter, contact quotient and periodicity of the electroglotographic waves of the singers in habitual voice. Method: A cross-sectional observational study, which selected individuals from singing schools in the central region of the municipality of Belo Horizonte. The sample was non-probabilistic, for convenience consisted of 60 singers aged between 18 and 55 years, 30 males and 30 females. For the electroglotographic record collection, the Kay Pentax ™ CSL program, model 6103, the Electroglotographic module was used. The participants were placed in a seated position, and after cleaning the skin of the neck with 70% alcohol, two electrodes were placed on the wings of the thyroid cartilage at the level of the vocal folds. Subsequently, the participants were instructed to emit the vowel/a/sustained in a habitual way. The measurements of the fundamental frequency (f0), contact quotient (QC), electroglotographic jitter and periodicity of the electroglotographic wave were analyzed. The data were statistically analyzed using Minitab 17. Results: The parameters analyzed were statistically significant. The fundamental frequency (f0) was higher in females (226.91Hz) when compared to males (166.54Hz). The measure of contact quotient and periodicity was also higher in women (40.46% and 15.51% respectively) when compared to men (27.45% and 7.82, respectively). The jitter parameter was higher in men when compared to women. Conclusion: Women presented higher values in the fundamental frequency (f0), contact quotient (QC) and periodicity of the wave compared to men. The men presented the jitter value higher than that of the women
Subject: Voz
Laringe
Disfonia
Acústica da Fala
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ENG - DEPARTAMENTO DE ENGENHARIA ESTRUTURAS
ENG - DEPARTAMENTO DE ENGENHARIA MATERIAIS E DA CONSTRUÇÃO CIVIL
MED - DEPARTAMENTO DE FONOAUDIOLOGIA
MED - DEPARTAMENTO DE OFTALMOLOGIA E OTORRINOLARINGOLOGIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: 10.1590/2317-1782/20202019022
URI: http://hdl.handle.net/1843/62994
Issue Date: 2020
metadata.dc.url.externa: https://doi.org/10.1590/2317-1782/20202019022
metadata.dc.relation.ispartof: CoDAS
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Análise das medidas eletroglotográficas pdfa.pdf352.01 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.