Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/65416
Type: Tese
Title: Análise de contaminantes em amostras de água aplicando sistemas aquosos bifásicos (SAB) como método de extração
Other Titles: Analysis of contaminants in water samples applying aqueous two-phase systems (ATPS) as an extraction method
Authors: Junielly Tomaz Domingues
First Advisor: Guilherme Dias Rodrigues
First Co-advisor: Ricardo Mathias Orlando
First Referee: Renata Pereira Lopes Moreira
Second Referee: Nathália Vieira Barbosa
Third Referee: Rodinei Augusti
metadata.dc.contributor.referee4: Bruno Gonçalves Botelho
Abstract: O estudo da extração/partição para determinação do coeficiente de partição (K) dos hormônios 17α-etinilestradiol (EE2), levonorgestrel (LV), gestodeno (GD), acetato de ciproterona (AC) e valerato de estradiol (VE) obtidos de pílulas anticoncepcionais foi realizado na fase superior do Sistema Aquoso Bifásico (SAB) com posterior determinação por espectrofotometria Ultravioleta-Visível (UV-Vis). Os parâmetros de partição avaliados do sistema foram: o valor de pH do meio (3,00; 5,00; 7,00; 9,00 e 11,00); a natureza do eletrólito (Na2SO4, Li2SO4.H2O, MgSO4.7H2O, Na2C4H4O6.2H2O, Na3C6H5O7.2H2O) e do polímero (PEO1500, L64 e L35) formador do SAB; o comprimento da linha de amarração do sistema (CLA); a temperatura controlada do banho termostático (5,00; 15,0; 25,0; e 40,0 ºC); e a relação mássica das fases inferior e superior do sistema (mFI⁄mFS: 1/1, 2/1, 3/1, 4/1 e 5/1). Essa avaliação foi realizada através de otimização univariada e multivariada, empregando planejamento experimental. A condição otimizada para todos os hormônios foi L35 + Na2SO4 + H2O, em pH = 3,00, CLA = 64,06% m/m, T = 25 °C e mFI/mFS = 5/1. Essa condição de extração dos hormônios foi aplicada em amostras de água potável, água de lagoa e rio e água filtrada de uma estação de tratamento de água e mostrou resultados promissores, diante dos altos sinais analíticos dos hormônios obtidos da fase superior do SAB. A validação do método de preparo de amostra utilizando SAB e quantificação de amoxicilina a partir do UPLC-MS/MS também foi realizada. A faixa linear determinada foi de 0 – 750 µg L-1, com limite de quantificação (LQ) de 30 µg L-1. A precisão e exatidão foram avaliadas em três níveis de concentração (30, 250 e 750 µg L-1), alcançando coeficientes de variação menores que 3% e recuperações maiores que 92%.
Abstract: The study of the extraction/partition for determination of partition coefficient (K) of the hormones 17α-ethinylestradiol (EE2), levonorgestrel (LV), gestodene (GD), cyproterone acetate (AC) and estradiol valerate (VE) obtained from birth control pills was carried out in aqueous two-phase system (ATPS) upper phase with later determination by ultraviolet-visible spectrophotometry (UV-Vis). The partition parameters evaluated for the system were: pH (3.00; 5.00; 7.00; 9.00 and 11.00); ATPS forming electrolytes (Na2SO4, Li2SO4.H2O, MgSO4.7H2O, Na2C4H4O6.2H2O, Na3C6H5O7.2H2O) and polymers (PEO1500, L64 and L35); tie-line length (TLL); temperature (5.00; 15.0; 25.0; and 40.0 ºC); and mass ratio between top and bottom phases (mBP/mTP: 1/1, 2/1, 3/1, 4/1 and 5/1). This evaluation was carried out through univariate and multivariate optimization, using experimental design. It was observed, for the first time, interactions of TLL and polymer with temperature, directly influencing the partition of hormones in ATPS. The best conditions obtained for all hormones was L35 + Na2SO4 + H2O, at pH = 3.00, TLL = 64.06% w/w, T = 25 ° C and mBP/mTP = 5/1. This condition of hormone extraction was applied to samples of drinking water, lake and river water and filtered water from a water treatment plant and showed promising results, given the high analytical signals of the hormones obtained from the upper phase of the ATPS. The validation of the sample preparation method using ATPS and amoxicillin quantification from the UPLC-MS/MS was also performed. The linear range determined was 0 – 750 µg L-1, with a quantification limit (LQ) of 30 µg L-1. Precision and accuracy were evaluated at three concentration levels (30, 250 and 750 µg L-1), reaching coefficients of variation less than 3% and recoveries greater than 92%.
Subject: Química analítica
Extração (Química)
Espectrofotometria
Cromatografia líquida
Espectrometria de massa
Preparação de amostra (Química)
Águas residuais - Análise
Impacto ambiental
Fármacos
Hormônios
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ICX - DEPARTAMENTO DE QUÍMICA
metadata.dc.publisher.program: Programa de Pós-Graduação em Química
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/65416
Issue Date: 7-Nov-2022
Appears in Collections:Teses de Doutorado

Files in This Item:
File Description SizeFormat 
Tese_doutorado_Junielly_PDFA.pdfTese de doutorado1.44 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.