Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/65951
Type: Dissertação
Title: Avaliação de um fotorreator simplificado de radiação UV utilizado na inativação de coliformes e ovos de helmintos em esgotos tratados
Authors: João Carlos de Castro Silva
First Advisor: Carlos Augusto de Lemos Chernicharo
First Referee: Marcelo Libânio
Second Referee: Marcos Von Sperling
Third Referee: Willer Hudson Pos
Abstract: Esta pesquisa avaliou a aplicabilidade de um fotorreator simplificado de radiação ultravioleta, para a inativação de coliformes totais, Escherichia coli e ovos de Ascaris lumbricoides, presentes em efluentes de um reator UASB e de um Filtro Biológico Percolador. O fotorreator, com volume de 2,2 L e confeccionado com tubo de PVC diâmetro de 100 mm, foi equipado com uma lâmpada imersa, de baixa pressão de mercúrio, com potência de 15 W. O fotorreator foi testado para a desinfecção de efluentes de um filtro biológico percolador e de um reator UASB, ambos alimentados com esgoto doméstico proveniente do interceptor de esgotos do ribeirão Arrudas, na cidade de Belo Horizonte. Os resultados obtidos demonstraram a aplicabilidade dos fotorreatores para a desinfecção de esgotos tratados, tendo sido observadas elevadas eficiências médias de inativação de coliformes totais e de E. coli, na faixa entre 4 e 5 unidades logarítmicas, para doses variando entre 13,6 e 102,43 mW.s/cm2. A exposição à radiação ultravioleta afetou, significativamente, o desenvolvimento dos ovos de Ascaris, sendo que os melhores resultados foram obtidos para doses entre 13,6 e 20,3 mW.s/cm2, quando apenas cerca de 10% dos ovos completaram o desenvolvimento até a etapa de larva. Os resultados obtidos mostram a aplicabilidade da radiação ultravioleta como póstratamento de sistemas UASB/Filtro Biológico.
Abstract: This research evaluated the applicability of a simplified ultraviolet radiation photoreactor, for the inactivation of total coliforms, Escherichia coli and Ascaris lumbricoides eggs, present in effluents from a UASB reactor and a Biological Percolator Filter. The photoreactor, with a volume of 2.2 L and made of PVC pipe with a diameter of 100 mm, was equipped with an immersed lamp, with low mercury pressure, with a power of 15 W. The photoreactor was tested for the disinfection of wastewater a biological percolating filter and a UASB reactor, both fed with domestic sewage from the sewage interceptor of the Arrudas stream, in the city of Belo Horizonte. The results obtained demonstrated the applicability of photoreactors for the disinfection of treated sewage, with high average inactivation efficiencies of total coliforms and E. coli being observed, in the range between 4 and 5 logarithmic units, for doses ranging between 13.6 and 102 .43 mW.s/cm2. Exposure to ultraviolet radiation significantly affected the development of Ascaris eggs, with the best results being obtained for doses between 13.6 and 20.3 mW.s/cm2, when only around 10% of the eggs completed development. until the larval stage. The results obtained show the applicability of ultraviolet radiation as post-treatment of UASB/Biological Filter systems.
Subject: Engenharia sanitária
Saneamento
Radiação ultravioleta
Microrganismos
Reator UASB
Ascaris lumbricoides
Escherichia coli
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ENG - DEPARTAMENTO DE ENGENHARIA SANITÁRIA E AMBIENTAL
metadata.dc.publisher.program: Programa de Pós-Graduação em Saneamento, Meio Ambiente e Recursos Hídricos
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/65951
Issue Date: 7-Mar-2002
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Dissertação - João Carlos.pdf4.04 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.