Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/67499
Tipo: Artigo de Periódico
Título: Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: a cross-sectional study
Autor(es): Frederico Santos Lages
Dhelfeson Willya Douglas-de-Oliveira
Guilherme Siqueira Ibelli
Fatimah Assaf
Thallita Pereira Queiroz
Fernando de Oliveira Costa
Resumo: Resonance frequency analysis (RFA) has become the main tool used to assess the osseointegration of dental implants. The objective of this study was to verify the relationship between the ISQ values with different prosthetic abutments and with the implant platform. The hypothesis was that ISQ values changes according to the abutment height. Twelve patients were included, whose contribution to the study was 31 dental implants (external hexagon connection implants, 4.1x10 mm). The temporary implant-supported crown and prosthetic components were removed and the following smartpegs were inserted, one at a time: type 1, in the implant platform (G1); type A3, in the microunit component with 1mm transmucosal height (G2) and type A3, in the microunit component with 5mm transmucosal height (G3). In all the smartpegs, RFA measurements were taken on mesial, distal, buccal and lingual surfaces. All evaluations were performed by a single calibrated examiner (ICC = 0.989). Data were analyzed by Friedman and Spearman correlation tests and log-linear marginal regression (p<0.05). The mean age of participants was 52.83 (± 3.77) years. There was statistically significant difference (p<0.001) among the mean ISQ of G1 (88.27 ±5.70); G2 (72.75 ±4.73) and G3 (66.33 ±3.67). There was statistically significant negative correlation between the ISQ and the measurement distance (rs:-0.852; p<0.001; R2:0.553). Measurement distance was significantly associated (p<0.001) with ISQ value in the log-lin ear regression. The abutment height has a significant impact on resonance frequency analy sis measurements. The higher the transmucosal abutment height, the lower the implant stability quotient value. Clinically, the ISQ measured on the abutment cannot be compared with values measured on the implant platform.
Assunto: Dental implants
Resonance frequency analysis
Osseointegration
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: FAO - DEPARTAMENTO DE CLÍNICA
Tipo de Acesso: Acesso Aberto
Identificador DOI: https://doi.org/10.1371/journal.pone.0181873
URI: http://hdl.handle.net/1843/67499
Data do documento: 24-Jul-2017
metadata.dc.url.externa: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0181873
metadata.dc.relation.ispartof: Plos One
Aparece nas coleções:Artigo de Periódico



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.