Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/67846
Type: Artigo de Periódico
Title: Assessment of polycyclic aromatic hydrocarbons and derivatives in beer using a new cold fiber-solid phase microextraction system
Authors: Rosimeire Resende dos Santos
Ricardo Mathias Orlando
Zenilda de Lourdes Cardeal
Helvécio Costa Menezes
Abstract: Sample preparation assisted by a cooling system including solid phase microextraction (SPME) has received an increased interest in recent years. In this work, a new cold fiber (CF-SPME) system using thermoelectric cooling is proposed. The system consists of three thermoelectric coolers (Peltier), a heat sink, a recirculation module to dissipate the heat generated on the hot side, and an electric power source to generate the necessary voltage for the system. The Peltier keeps the SPME fiber cool during the extraction process.. This system was used to analyze polycyclic aromatic hydrocarbons (PAHs), and their nitrated (nitro-PAHs) and oxygenated (oxy-PAHs) derivatives, in commercial beers b gas chromatography coupled to mass spectrometry (GC/MS). The analyte's extraction was optimized through Doehlert design. Optimal extraction conditions were obtained with a salt content of 0.6% w/v and beer volume of 700.0 μL. The validated method showed limits of detection (LOD) in the range of 0.003–0.128 μg L−1 and limits of quantification (LOQ) from 0.011 to 0.427 μg L−1. Precision Coefficients of Variation values ranged from 3.0 to 18.7%, and recovery values of the analytes in beer varied between 80.1 and 100.3%. Among the PAHs derivatives evaluated in this study, only 9-fluorenone and 9-nitroanthracene were detected in some samples. Benzo[b]fluoranthene was the most detected analyte in the samples, and at least one PAH was detected in all samples. Principal component analysis (PCA) separated the samples into two groups, mainly due to the high relative concentrations of acenaphthene and chrysene. The cooling approach improved the extraction efficiency and the new system demonstrated high potential for portability and automation.
Subject: Preparação de amostra (Química)
Cerveja
Hidrocarbonetos policiclicos aromaticos
Cromatografia de gás
language: eng
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ICX - DEPARTAMENTO DE QUÍMICA
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1016/j.foodcont.2021.108104
URI: http://hdl.handle.net/1843/67846
Issue Date: 2021
metadata.dc.url.externa: https://www.sciencedirect.com/science/article/pii/S0956713521002425
metadata.dc.relation.ispartof: Food Control
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.