Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/76768
Type: Artigo de Evento
Title: Influência do fluxo de injeção de contraste no exame de TC para o diagnóstico de embolismo pulmonar
Other Titles: Influence of contrast injection flow on CT examination for the diagnosis of pulmonary embolism
Authors: Warley Ferreira Felix
Marcos Eugênio Silva Abrantes
Maria Auxiliadora Fortini Veloso
Abstract: A angiotomografia para tromboembolismo pulmonar é um exame de realização complexa, onde fatores como, tempo, fluxo, acesso venoso, local de punção, entre outros, interferem no desfecho do exame. Analisando a influência da variação do fluxo de injeção de contraste venoso na contrastação da região de interesse, foram encontrados os resultados de: injeção manual (194,9±141,2); 3,0 ml/s, 90 UH (216, 6±113,3); 3,5ml/s, 90 UH (286,5±106,6); 4,0ml/s, 90 UH (300,2±58,8); 4,0ml/s, 80 UH (328,3±110,3); 4,5ml/s, 80 UH (377,0±114,6); 5,0ml/s, 80 UH (348,9±136,8). A técnica com melhor resultado foi aquela que utilizou fluxo de 4,5 ml/s e disparo automático em 80 UH.
Abstract: The angiotomography for pulmonary thormboembolism is an examination of complex realization, where factors such as, time, flow, venous access, puncture site, among others, interfere in the outcome of the examination. Analyzing the influence of the variation of the venous contrast injection flux in contrast of the region of interest, the results were found: manual injection (194.9±141.2); 3.0 ml/s, 90 HU (216.6±113.3); 3.5ml/S, 90 HU (286.5±106.6); 4.0 ml/s, 90 HU (300.2±58.8); 4.0 ml/s, 80 HU (328.3±110.3); 4.5ml/S, 80 HU (377.0±114.6); 5.0ml/s, 80 HU (348.9±136.8). Observing that the technique with best result was used a 4.5 ml/s flow and automatic trigger at 80 HU.
Subject: Tomografia
Embolia Pulmonar
Análise Instrumental
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: HCL - HOSPITAL DAS CLINICAS
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/76768
Issue Date: 2018
metadata.dc.url.externa: https://inis.iaea.org/collection/NCLCollectionStore/_Public/50/025/50025863.pdf
metadata.dc.relation.ispartof: Congresso Brasileiro de Metrologia das Radiações Ionizantes
Appears in Collections:Artigo de Evento

Files in This Item:
File Description SizeFormat 
Influência do fluxo de injeção.pdfA.pdf395.05 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.