Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/76768
Type: | Artigo de Evento |
Title: | Influência do fluxo de injeção de contraste no exame de TC para o diagnóstico de embolismo pulmonar |
Other Titles: | Influence of contrast injection flow on CT examination for the diagnosis of pulmonary embolism |
Authors: | Warley Ferreira Felix Marcos Eugênio Silva Abrantes Maria Auxiliadora Fortini Veloso |
Abstract: | A angiotomografia para tromboembolismo pulmonar é um exame de realização complexa, onde fatores como, tempo, fluxo, acesso venoso, local de punção, entre outros, interferem no desfecho do exame. Analisando a influência da variação do fluxo de injeção de contraste venoso na contrastação da região de interesse, foram encontrados os resultados de: injeção manual (194,9±141,2); 3,0 ml/s, 90 UH (216, 6±113,3); 3,5ml/s, 90 UH (286,5±106,6); 4,0ml/s, 90 UH (300,2±58,8); 4,0ml/s, 80 UH (328,3±110,3); 4,5ml/s, 80 UH (377,0±114,6); 5,0ml/s, 80 UH (348,9±136,8). A técnica com melhor resultado foi aquela que utilizou fluxo de 4,5 ml/s e disparo automático em 80 UH. |
Abstract: | The angiotomography for pulmonary thormboembolism is an examination of complex realization, where factors such as, time, flow, venous access, puncture site, among others, interfere in the outcome of the examination. Analyzing the influence of the variation of the venous contrast injection flux in contrast of the region of interest, the results were found: manual injection (194.9±141.2); 3.0 ml/s, 90 HU (216.6±113.3); 3.5ml/S, 90 HU (286.5±106.6); 4.0 ml/s, 90 HU (300.2±58.8); 4.0 ml/s, 80 HU (328.3±110.3); 4.5ml/S, 80 HU (377.0±114.6); 5.0ml/s, 80 HU (348.9±136.8). Observing that the technique with best result was used a 4.5 ml/s flow and automatic trigger at 80 HU. |
Subject: | Tomografia Embolia Pulmonar Análise Instrumental |
language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Universidade Federal de Minas Gerais |
Publisher Initials: | UFMG |
metadata.dc.publisher.department: | HCL - HOSPITAL DAS CLINICAS |
Rights: | Acesso Aberto |
URI: | http://hdl.handle.net/1843/76768 |
Issue Date: | 2018 |
metadata.dc.url.externa: | https://inis.iaea.org/collection/NCLCollectionStore/_Public/50/025/50025863.pdf |
metadata.dc.relation.ispartof: | Congresso Brasileiro de Metrologia das Radiações Ionizantes |