Refrigerant selection for a chiller air conditioning system in Brazil

dc.creatorAlex Henrique Coutinho Santos
dc.creatorTiago de Freitas Paulino
dc.creatorDaniele Marques Ferreira
dc.creatorPaulo Eduardo Lopes Barbiere
dc.date.accessioned2023-09-07T00:08:05Z
dc.date.accessioned2025-09-08T23:11:44Z
dc.date.available2023-09-07T00:08:05Z
dc.date.issued2022
dc.format.mimetypepdf
dc.identifier.urihttps://hdl.handle.net/1843/58540
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.rightsAcesso Aberto
dc.rightsAtribuição 3.0 Portugal
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pt/
dc.subjectAr condicionado
dc.subject.otherRefrigerant selection
dc.subject.otherMathematical model
dc.subject.otherAir conditioning system
dc.titleRefrigerant selection for a chiller air conditioning system in Brazil
dc.typeArtigo de evento
local.citation.epage10
local.citation.issue19
local.citation.spage1
local.description.resumoIn 2017, electrical air conditioning systems represent an approximate consumption of 20% of the total electrical energy consumed in Brazilian homes. In addition, air conditioning systems may account for 85% of the consumption of residential electric energy in the peak of summer and in commercial establishments approximately 40% of the electric energy consumed is destined for the acclimatization of environments. An innovative technology that can collaborate to mitigate environmental problems and make energy consumption more efficient is thermal energy storage (TES). The TES also helps to decouple the cooling production and the use of it. In that way the cold should be produced during the night, for example and use during the day. This paper proposes a mathematical model using Python language and CoolProp for refrigerant properties. A chiller refrigerant system able to meet a colling capacity of 15 TR is selected. It simulates the operation of refrigeration systems to evaluate the coefficient of performance (COP) during the year of 2020 for three cities in different regions in Brazil: Fortaleza - CE (Northeast), Brasília - DF (Midwest) and Monte Verde – MG (Southeast). In each city will verify the efficiency of three different refrigerant fluids, R134a, R1234yf and R717. The mathematical model of refrigeration system considers a chiller with a TES (Thermal Energy System) to produce and storage cold during the night to be consumed during the day, specially at the peak time. As the condition in the evaporator are keep constant in the system, the model consider only the compressor and the condenser. The mathematical model applied in this study make a comparison between the refrigerant fluids, where R134a is considered as a reference, and comparing with R1234yf and R717. The objective of the manuscript is to select the refrigerant that best suit to the context of the selected cities, considering R134a as a reference, we have that the COP of R717 is greater by about 16.1% for Fortaleza - CE, 14.6% for Brasília - DF and 13.2% for Monte Verde - MG
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICA
local.publisher.initialsUFMG

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
REFRIGERANT SELECTION FOR A CHILLER AIR CONDITIONING.pdf
Tamanho:
407.19 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.07 KB
Formato:
Plain Text
Descrição: