Diagnostic performance of commercially available COVID-19 serology tests in Brazil

dc.creatorGláucia Fernandes Cota
dc.creatorMariana Lourenço Freire
dc.creatorCarolina Senra Alves de Souza
dc.creatorMariana Junqueira Pedras
dc.creatorJuliana Wilke Saliba
dc.creatorVerônica Cardoso Santos de Faria
dc.creatorLíndicy Leidicy Alves
dc.creatorAna Lúcia Teles Rabello
dc.creatorDaniel Moreira Avelar
dc.date.accessioned2023-04-17T21:49:24Z
dc.date.accessioned2025-09-08T23:03:13Z
dc.date.available2023-04-17T21:49:24Z
dc.date.issued2020-12
dc.description.abstractTestes laboratoriais oportunos e precisos são essenciais para o gerenciamento da pandemia global de COVID-19. A reação em cadeia da polimerase com transcrição reversa continua sendo o padrão-ouro para o diagnóstico de SARS-CoV-2, mas várias questões práticas limitam o uso do teste. Os imunoensaios têm sido indicados como alternativa para testes individuais e em massa. Objetivos: Acessar a realização de 12 testes sorológicos para diagnóstico de COVID-19. Métodos: Realizamos uma avaliação cega de seis imunoensaios de fluxo lateral (LFIAs) e seis ensaios imunoenzimáticos (ELISAs) disponíveis comercialmente no Brasil para detecção de anticorpos anti-SARS-CoV-2. Resultados: Considerando pacientes com sete ou mais dias de sintomas, a sensibilidade variou de 59,5% a 83,1% para LFIAs e de 50,7% a 92,6% para ELISAs. Para ambos os métodos, a sensibilidade aumentou com a gravidade clínica e os dias de sintomas. A concordância entre os LFIAs realizados com sangue digital e soro foi moderada. A especificidade foi, em geral, maior para LFIAs do que para ELISAs. Doenças infecciosas prevalentes nos trópicos, como HIV, leishmaniose, arboviroses e malária, representam condições com potencial para causar resultados falso-positivos com esses testes, o que compromete significativamente sua especificidade. Conclusão: O desempenho dos imunoensaios foi apenas moderado, influenciado pela duração e gravidade clínica da doença. Também foi demonstrada ausência de poder discriminatório entre IgM/IgA e IgG, o que impede o uso de anticorpos de fase aguda para decisões de isolamento social.
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
dc.format.mimetypepdf
dc.identifier.doihttps://doi.org/10.1016/j.ijid.2020.10.008
dc.identifier.issn1201-9712
dc.identifier.urihttps://hdl.handle.net/1843/52094
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofInternational Journal of Infectious Diseases
dc.rightsAcesso Aberto
dc.subjectCOVID-19 (Doença)
dc.subjectCOVID-19 Pandemia, 2020
dc.subjectSARS-CoV-2
dc.subjectTeste para COVID-19
dc.subjectTeste sorológico para COVID-19
dc.subjectTestes de diagnóstico rápido
dc.subject.otherAntibody
dc.subject.otherCOVID-19
dc.subject.otherPerformance
dc.subject.otherSARS-CoV-2
dc.subject.otherRapid test
dc.subject.otherSerology
dc.subject.otherDiagnosis
dc.subject.otherAccuracy
dc.titleDiagnostic performance of commercially available COVID-19 serology tests in Brazil
dc.title.alternativeDesempenho diagnóstico de testes de sorologia COVID-19 disponíveis comercialmente no Brasil
dc.typeArtigo de periódico
local.citation.epage390
local.citation.spage382
local.citation.volume101
local.description.resumoTimely and accurate laboratory testing is essential for managing the global COVID-19 pandemic. Reverse transcription polymerase chain reaction remains the gold-standard for SARS-CoV-2 diagnosis, but several practical issues limit the test’s use. Immunoassays have been indicated as an alternative for individual and mass testing. Objectives: To access the performance of 12 serological tests for COVID-19 diagnosis. Methods: We conducted a blind evaluation of six lateral-flow immunoassays (LFIAs) and six enzymelinked immunosorbent assays (ELISAs) commercially available in Brazil for detecting anti-SARS-CoV-2 antibodies. Results: Considering patients with seven or more days of symptoms, the sensitivity ranged from 59.5% to 83.1% for LFIAs and from 50.7% to 92.6% for ELISAs. For both methods, the sensitivity increased with clinical severity and days of symptoms. The agreement among LFIAs performed with digital blood and serum was moderate. Specificity was, in general, higher for LFIAs than for ELISAs. Infectious diseases prevalent in the tropics, such as HIV, leishmaniasis, arboviruses, and malaria, represent conditions with the potential to cause false-positive results with these tests, which significantly compromises their specificity. Conclusion: The performance of immunoassays was only moderate, affected by the duration and clinical severity of the disease. Absence of discriminatory power between IgM/IgA and IgG has also been demonstrated, which prevents the use of acute-phase antibodies for decisions on social isolation.
local.identifier.orcidhttps://orcid.org/0000-0003-0538-7403
local.identifier.orcidhttps://orcid.org/0000-0003-3380-2651
local.identifier.orcidhttps://orcid.org/0000-0003-2494-6178
local.identifier.orcidhttps://orcid.org/0000-0001-7907-7913
local.publisher.countryBrasil
local.publisher.departmentHCL - HOSPITAL DAS CLINICAS
local.publisher.initialsUFMG
local.url.externahttps://www.sciencedirect.com/science/article/pii/S1201971220322116?via%3Dihub

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Diagnostic performance of commercially available COVID-19 serology tests in Brazil.pdf
Tamanho:
317.79 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: