Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/57646
Tipo: Artigo de Periódico
Título: TiO2 sol-gel coating as a transducer substrate for impedimetric immunosensors
Autor(es): Ricardo Adriano Dorledo de Faria
Manuel Noel Paul Georges Houmard
Verônica Aparecida Martins do Rosário
Vanessa de Freitas Cunha Lins
Luiz Guilherme Dias Heneine
Tulio Matencio
Resumen: Given the importance of the transducer elements in the performance of sensors for various applications, as well as the growing search for devices that are capable of providing the response in shorter time, in this work, titanium dioxide was examined as a candidate for application in an electrochemical biosensor. A TiO2 coating deposited by sol-gel method on a silicon wafer was obtained with an anatase crystalline structure, as an n-type semiconductor with donor density equal to 2.954 · 1017 cm–3. Its surface was functionalized to be tested as a biosensor to detect snake venom of the Bothrops genera, and each step of the functionalization was investigated using Electrochemical Impedance Spectroscopy (EIS) and Cyclic voltammetry. Despite being less sensitive than the reference method ELISA, the TiO2-based biosensor was also capable of detecting the analyte of interest at 20 μg mL–1, revealing an increase in its leakage resistance and phase shift after incubation in this solution. Furthermore, the total time for carrying out the biodetection with the TiO2-coated device (41.24 ± 0.05 min) was estimated to be approximately 80 % shorter than that required by the labelled standard assay, which indicates that TiO2 is a promising electrochemical transducer for biosensing applications.
Asunto: Eletroquímica
Espectroscopia de impedância
Dióxido de titânio
Biossensores
Detectores eletroquímicos
Voltametria
Cobra venenosa — Veneno
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Departamento: ENG - DEPARTAMENTO DE ENGENHARIA QUÍMICA
ICX - DEPARTAMENTO DE QUÍMICA
Tipo de acceso: Acesso Aberto
Identificador DOI: https://doi.org/10.15255/CABEQ.2019.1699
URI: http://hdl.handle.net/1843/57646
Fecha del documento: 2019
metadata.dc.url.externa: http://silverstripe.fkit.hr/cabeq/past-issues/article/1699
metadata.dc.relation.ispartof: Chemical and Biochemical Engineering Quarterly
Aparece en las colecciones:Artigo de Periódico

archivos asociados a este elemento:
archivo Descripción TamañoFormato 
Tio2 sol-gel coating as a transducer substrate for impedimetric immunosensors.pdf539.92 kBAdobe PDFVisualizar/Abrir


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.